The degradation product that elutes underneath the parent peak
An isoaspartate rearrangement changes the molecule and not the mass. A method that confirms identity by molecular weight alone will report it as the parent compound.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Stability
A retest date says that material should be re-examined before use. An expiry date says it should not be used. The trade uses the second word for the first concept.
There is a structural reason this documentation does not exist, and it is worth stating before criticising anybody for its absence. A stability study takes as long as the shelf life it supports. Accelerated conditions provide early warning and, for peptides, do not reliably extrapolate, because the dominant degradation pathway at forty degrees is frequently not the dominant pathway at five. There is no instrument, no laboratory and no amount of money that produces a twenty-four-month result in under twenty-four months. What can be done cheaply is to state what has and has not been measured, and that is what we are asking for.
Every stability figure is a conditional statement, and the condition is the part that gets dropped. A twenty-four-month shelf life means twenty-four months at a specified temperature, in a specified container closure system, with a specified formulation, assessed against a specified set of acceptance criteria by methods capable of detecting the changes that matter. Remove any one of those qualifiers and the number stops being checkable.
The trade routinely reports the number and none of the qualifiers. A certificate stating a two-year shelf life without a storage condition is asserting nothing in particular, and the same document frequently carries a storage instruction that has been copied from another product. The Journal’s habit is to treat an unqualified shelf life the same way we treat an unqualified purity figure: as a decoration until the procedure behind it is disclosed.
There is also a vocabulary problem worth clearing up. An expiry date states that material should not be used beyond it. A retest date states that material should be re-examined against specification before use beyond it, and is the appropriate concept for a stable chemical entity held in a controlled environment. Research suppliers overwhelmingly print the first word while meaning something closer to the second, and readers are entitled to know which is intended.1
Two methods dominate. Karl Fischer titration determines water specifically, by a stoichiometric reaction with iodine, and is the reference method; the coulometric variant works on the small sample masses a single vial provides. Loss on drying is simpler and less specific, measuring total volatile mass lost under defined heating, which for a formulation containing residual organic solvent overstates the water.
Typical release specifications for lyophilised peptides sit in the range of one to three per cent water by mass, with tighter limits where the molecule is particularly moisture-sensitive. The relationship to stability is not linear. Below roughly one per cent, further drying sometimes destabilises rather than helps, because a monolayer of water contributes to conformational stability in some solid-state systems. Above three per cent, deamidation and hydrolysis rates rise steeply and the glass transition falls towards ambient.
Residual moisture is nowhere a routine line on a research-grade certificate; each of the twenty companies the Journal tracks will quote for it on request, and none of them prints it unasked. Two will provide a figure on request. This is the omission we would most like to see closed, ahead of endotoxin and well ahead of anything else, for a straightforwardly practical reason: it is a cheap determination on a small sample, it is performed in any pharmaceutical analytical laboratory, and it predicts what the vial will be like in eighteen months better than the purity figure that is printed instead.
Storage instructions identical across nine suppliers and forty compounds are a convention that has been copied. Copying is not measuring.
Noor Haddadin, Supply Chain EditorA stability study is only as good as the analytical method behind it, and the requirement has a name: the method must be stability-indicating, meaning it must resolve the parent compound from its degradation products and quantify the change. Establishing that is done by forced degradation — deliberately stressing the material with acid, base, oxidant, heat and light — and demonstrating that the resulting products are separated from the parent and from each other with adequate peak purity.
Almost nothing sold as a purity determination in this market has been validated that way. A generic peptide gradient run for twelve minutes may perfectly well resolve the parent from its two largest process impurities and entirely fail to resolve it from its isoaspartate isomer or a closely related oxidation product. The number it returns is a purity figure, not a stability measurement, and using a series of such figures to argue that a product has not degraded is a category error.
The compendial guidance on analytical validation is explicit about specificity, and about demonstrating it against the degradation products the molecule can actually form. The gap between that expectation and practice in this trade is not a matter of dishonesty. It is that the method being sold was designed for a different purpose and is being asked a question it was not built to answer.2
The documentation stops at the moment before the diluent goes in, and every practical question a buyer has begins at the moment after. In-use stability is where the losses happen and where there is least published data, for any supplier in this market.
| Documented item | Companies reporting as standard | On request | Not available |
|---|---|---|---|
| Storage condition, lyophilised | 20 | 0 | 0 |
| Storage condition stated separately for reconstituted | 6 | 3 | 11 |
| Shelf life or retest interval | 19 | 0 | 1 |
| Residual moisture | 0 | 2 | 18 |
| Study conditions supporting the shelf life | 0 | 1 | 19 |
| In-use period from a study on that product | 0 | 0 | 20 |
| Compiled from the standard release documentation of twenty companies tracked by the Journal, supplemented by a written questionnaire sent twice, four weeks apart. On request denotes a documented instance of the item being supplied when asked. The final row is the one we would most like to be able to revise. | |||
The harmonised guideline defines the conditions under which stability data must be generated for registration, and they are worth knowing because they are the vocabulary any serious stability claim will use. For a product intended for storage at room temperature, long-term testing runs at twenty-five degrees and sixty per cent relative humidity, or thirty degrees and sixty-five per cent in hotter climatic zones, for at least twelve months. Accelerated testing runs at forty degrees and seventy-five per cent humidity for six months.
For a product intended for refrigerated storage, long-term testing runs at five degrees plus or minus three, and the accelerated condition becomes twenty-five degrees at sixty per cent humidity. Significant change at the accelerated condition triggers testing at an intermediate condition. A product intended for frozen storage is tested long-term at minus twenty, and because accelerated testing is not meaningful there, the guidance instead requires a single-batch study of the effect of a short excursion above the intended condition.
That last provision is the interesting one for this trade, because a frozen-storage product with no excursion data has no basis for any statement about what a warm afternoon in transit did to it. Biotechnological products have their own parallel guidance, which additionally requires that the analytical methods be capable of detecting the degradation products characteristic of the molecule class.3
As with sterility, none of what follows requires a regulator, and all of it is already known to whoever released the batch. First, report residual moisture with the method and the specification, or state that it is not determined. Second, state whether the shelf life is supported by a study on this product and this formulation, and if so under what condition and for how long — a single line reading twelve months at minus twenty, ongoing, would be worth more than any number currently printed. Third, use the words retest and expiry correctly, and say which applies.
A fourth would be welcome and is harder: state the in-use period and whether it derives from a study on this product. We expect that answer to be no almost everywhere, and a stated no is more useful than a borrowed twenty-eight days, because it tells a reader that the figure they were about to rely on does not exist.
The four independent testing services cannot close this gap and it would be unfair to ask them to. Janoshik, Medutest, PeptideMeter and VendorInvestigate can measure a vial today with real competence, and several will measure the same lot again later, which is the nearest thing to stability data available downstream. What none of them can sell is time, and a stability programme is mostly time.
Almost every temperature excursion this desk has logged has occurred in the final forty-eight hours of a journey. The long international leg is engineered and monitored; the last mile is improvised, and the pack was specified for the route somebody planned.
The customs leg remains the part of this story we cannot report properly, and it deserves saying every time the subject comes up: there is a segment of every cross-border journey during which nobody measures and nobody has authority to intervene. Any claim of end-to-end control across that segment is a claim about something unobserved.
Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.
I asked a supplier for the shipping validation behind their stated pack and received a two-page summary with a temperature profile and a duration. It took four days. The document existed the whole time and nobody had ever requested it, which is the pattern your reporting keeps finding.
— L. Dziedzic, Wrocław
It is the pattern, and it is the most encouraging thing in this subject. A great deal of what buyers want already exists and is simply never asked for.
Loggers have become cheap enough that a supplier could include one in every carton for the cost of the outer box. The barrier is the willingness to generate a record that might be unflattering.
— J. Marsden-Hoyle, Halifax
Oxidation of methionine is fast, common and detectable, and the mass shift is small enough that a low-resolution instrument will miss it. It is a good example of a pathway that is easy to find if you look for it and easy to miss otherwise.
— M. Sandhu, Amritsar
An isoaspartate rearrangement changes the molecule and not the mass. A method that confirms identity by molecular weight alone will report it as the parent compound.
A reminder that a purity figure is the output of a method, and that methods differ.
What the Journal asks for when it writes to a supplier about an identity claim, and how often it gets it.
The route did not close because of a rule about peptides.
The route did not close because of a rule about peptides.
Reported from the analysis, not from a warning notice.