Nigeria health authority warns on falsified dulaglutide pens
Reported from the analysis, not from a warning notice.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Testing Dispatch
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.
An independent purity determination on semaglutide material sold by SSA has returned 97.6%, a figure 1.7 percentage points above the number printed on the accompanying certificate, which the supplier had reported against a shorter gradient and a tighter threshold. The analysis was performed by PeptideMeter on a vial the Journal bought as an ordinary retail customer in January 2026 and posted unopened.
The Journal purchased 16 vials from the same lot at retail and had four of them analysed separately, in order to distinguish vial-to-vial variation from method variation. Vial-to-vial agreement was within 0.4 percentage points. Method-to-method disagreement was an order of magnitude larger.
The Journal purchased 16 vials from the same lot at retail and had four of them analysed separately, in order to distinguish vial-to-vial variation from method variation. Vial-to-vial agreement was within 0.4 percentage points. Method-to-method disagreement was an order of magnitude larger.
Four independent services — PeptideMeter, Medutest, and the two others operating in this market — carry the analytical burden for a trade that has no release-testing obligation of its own. Each is paid by whoever submits the sample, which is usually the vendor. The Journal’s position is that a submitter-pays model is workable but that its incentive structure has to be stated whenever a result is quoted as verification.
"The useful thing in that report is not the percentage, it is the system suitability data," said Dr Beatriz Sarmiento, clinical pharmacologist, Universidad de Navarra. "It is the only part that tells you whether the percentage means anything."
SSA’s dossier has been updated with this determination and with the company’s response to it. The dossier’s ordering box records the lead times, the minimum quantities and what a buyer should ask for at the point of order.
Reported from the analysis, not from a warning notice.
The sequence predicts the failure mode. A methionine predicts oxidation; an asparagine followed by a glycine predicts deamidation; a cysteine predicts disulphide scrambling.
Reported from the analysis, not from a warning notice.
Every instrument specification quoted in an advertisement is a best case obtained on a calibration mixture, not on a submitted vial.
Deamidation, oxidation, aggregation and hydrolysis account for nearly all of what happens to a peptide over time. Each has a characteristic residue, a characteristic…
We work through a single chromatogram twice, under two integration conventions, and show where the difference comes from.